BIO-RAD CFX96 TOUCH REAL-TIME PCR DETECTION SYSTEM — C1000 TOUCH CHASSIS + CFX96 OPTICS — 280 TOTAL HOURS

BIO-RAD CFX96 TOUCH REAL-TIME PCR DETECTION SYSTEM — C1000 TOUCH CHASSIS + CFX96 OPTICS — 280 TOTAL HOURS
$7,500 (USD)
Location:Vancouver, WA
Description
C1000 Touch Thermal Cycler chassis — Base S/N CT004468
CFX96 Optical Reaction Module — S/N 785BR08546, manufactured 07/2012
CFX96 block, 96 × 0.2 ml — Block S/N RN031028
Complete six-channel qPCR system for gene expression, genotyping, pathogen detection, and multiplex assays. The CFX96 optics module turns the C1000 Touch chassis into a full real-time instrument with five-target multiplexing in a single well, and the system runs stand-alone from the touchscreen or under PC control.
The number that matters: 280 total hours, displayed on the instrument's own About screen and photographed. For a platform rated for years of continuous service, this unit has barely been used.
CONDITION
Used — Inspected and functionally tested. Powers on, lid actuates, and the instrument was run under remote control from Bio-Rad CFX Maestro software with a protocol loaded (see photographs). Clean block and optics; light cosmetic wear on the housing.
SPECIFICATIONS
• Optical detection: six channels — five colors plus one FRET channel; 6 filtered LEDs, 6 filtered photodiodes, 450–730 nm
• Multiplexing: up to 5 targets per well
• Scan time: 12 sec all channels; 3 sec FAM/SYBR Green only
• Sensitivity: 1 copy of target in human genomic DNA; 10 orders dynamic range
• Block: 96 × 0.2 ml, Peltier; max ramp 5 °C/sec, average 3.3 °C/sec
• Temperature range 0–100 °C; accuracy ±0.2 °C at 90 °C; uniformity ±0.4 °C well-to-well
• Gradient: 30–100 °C operational, 1–24 °C programmable span
• Heated lid to 105 °C
• Connectivity: Ethernet, 2× USB-A host, USB device port; front USB for data export
• Research use only — not licensed for In Vitro Diagnostics
INCLUDED
• Bio-Rad C1000 Touch chassis with CFX96 optical reaction module and CFX96 block, as photographed
• Power cord and USB cable
Questions on software compatibility welcome — tell us your CFX Manager or CFX Maestro version and we will confirm.
Specifications
| Manufacturer | BIO-RAD |
| Model | CFX96 |
| Year | 2012 |
| Condition | Used |
| Serial Number | Base S/N CT004468, Module — S/N 785BR08546, Block S/N RN031028 |
| Stock Number | LT1011-X9 |
| Rotor Type | Fixed-Angle Rotor |
| Features | Microcentrifuge |
| Intended Use/Discipline | Biological Laboratory, Medical Laboratory, Microbiological Laboratory |