Biocare Medical Decloaking Chamber NxGen (DC2012) HIER System Used

Biocare Medical Decloaking Chamber NxGen (DC2012) HIER System Used

$1,000 (USD)

Shipping charges apply

Location:Vancouver, WA

Description

The Biocare Medical Decloaking Chamber NxGen is an industry-standard, programmable pressurized heating system specifically engineered for Heat-Induced Epitope Retrieval (HIER) in immunohistochemistry (IHC) and in situ hybridization (ISH) workflows. By maintaining strict, microprocessor-controlled temperature and pressure profiles, this unit ensures highly reproducible antigen unmasking. This standardization is critical for reducing background staining, preserving tissue morphology, and optimizing diagnostic readouts. The unit features an intuitive color digital display with built-in run charts and a front USB port for run-data logging and compliance tracking.

Condition Notes

  • Condition: Used / Inspected & Good Condition.
  • Functional Status: Visually and mechanically inspected. The unit successfully powers on, and the front digital screen is bright and responsive, booting successfully into firmware version V3.6.4.2. The locking lid engages properly, and the top pressure sensor cable/connection is intact. The heating element functions as expected during startup initialization.
  • Cosmetic Status: Very good used condition. The exterior stainless steel housing and heavy-duty plastic trims are structurally sound and clean, showing only minor surface wear typical of a clinical environment. The internal non-stick chamber is exceptionally clean and free of scaling or degraded coatings.
  • Serial Number: DC12- 0240

Technical Specifications

  • Brand: Biocare Medical
  • Model: Decloaking Chamber NxGen (DC2012)
  • Equipment Type: Heat-Induced Epitope Retrieval (HIER) System / Pressure Chamber
  • Software Version: V3.6.4.2
  • Compliance/Certifications: IVD, CE, ETL Listed
  • Data Interface: Front USB Port (for run logging)
  • Power Requirements: 115 VAC | 60 Hz | 1000 W

Included in this Package

  • (1) Biocare Medical Decloaking Chamber NxGen Base Unit
  • (1) Locking Lid with Integrated Pressure Sensor
  • (1) Biocare Medical Branded USB Flash Drive (Installed)

LT886-P5

Specifications

ManufacturerBiocare Medical
ModelNxGen DC2012
ConditionUsed
Serial NumberDC12- 0240
Stock NumberLT886-P5
* Serial NumberDC12- 0240
* BrandBiocare Medical
* ModelDecloaking Chamber NxGen (DC2012)
* Software VersionV3.6.4.2
* Compliance/CertificationsIVD, CE, ETL Listed